View Categories

1 min read

Bypassing zones on your DSC PowerSeries Neo alarm system lets you temporarily disable selected sensors so you can arm your system even if a door, window, or other zone is open or being serviced. This feature is especially useful when a zone is malfunctioning or you need access to a protected area while the rest of the system remains armed.


What “Zone Bypass” Means

When you bypass a zone, the alarm panel will ignore activity from that specific sensor during the next arming cycle. Bypassed zones won’t trigger alarms until they are restored or the system is disarmed.


Step-by-Step: How to Bypass Zones (LCD Keypad)

  1. Disarm the system.
    Zone bypassing cannot be done while the system is armed.
  2. Press the * key to open the function menu.
  3. Select “Zone Bypass.”
    Depending on your programming, you may need to press 1 or scroll to the option.
  4. Enter your access code if required by system settings.
  5. Choose the zone(s) you want to bypass.
    • Scroll to the zone name or enter the three-digit zone number.
    • Press * to bypass.
      A “B” appears next to the zone, indicating it’s bypassed.
  6. Exit to the home screen by pressing # until you’re back to Ready status.
  7. Arm the system normally.
    Only the zones you bypassed will be ignored during arming.

Important Notes

  • Bypasses are temporary. Once the system is disarmed, bypassed zones are automatically cleared and must be set again if needed.
  • If a zone is open and blocking arming, bypassing lets you arm without securing that zone first.